Send Email
Send SMS
Search
Micron


Hi-Link Power Modules

Prominent & Leading Wholesale Trader from Mumbai, we offer hilink pm12, hilink pm01, hilink 5m12 and hilink 5m05.

HILINK PM12

REQUEST CALLBACK

HILINK PM12
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 290 / NumberGet Latest Price

Features:
1. Ultra-thin, ultra-small
2. Input voltage: 110-240V AC
3. Low power consumption, environmental protection, no-load loss <0.1W
4. Low ripple, low noise
5. Good output short-circuit and over-current protection and self-recovery
6. High efficiency, high power density
7. Input and output isolation voltage 3000V
8. 100% full load aging and testing
9. High reliability, long life design, continuous working time is more than 100,000 hours
10. Meet the UL / CE requirements: product design to meet EMC and safety test requirements
11. Moisture, vibration, water and dust to meet IP65 standards Basic Parameters: 1. Operating temperature: -25 ~ 60 ¿¿¿2. Storage temperature: -40 ~ 80 ¿¿¿3. Relative humidity: 5 ~ 95%4. Cooling method: natural cooling5. Atmospheric pressure: 80 ~ 106 Kpa6. Altitude: ≤ 2000m7. Vibration coefficient: 10 ~ 500Hz, 2G10min / 1cycle 60min.each along X.Y, Z axes Electrical Characteristics: 1. Rated input voltage: 110 - 240Vac2. Input voltage range: 90-264V AC3. The maximum input current: ≤ 0.2A4. Input surge current: ≤10A5. The maximum input voltage: ≤ 270V6. Input low voltage efficiency: Vin = 110Vac, output full load ≥69%7. Input high voltage efficiency: Vin = 2200Vac, output full load ≥70%8. Long-term reliability: MTBF ≥ 100,000H9. External fuse Recommended: 1A / 250Vac10.No-load rated output voltage: 12 ± 0.1Vdc11. Full load rated output voltage: 12 ± 0.2Vdc12. Short time maximum output current: ≥650mA
13. Long time maximum output current: ≥ 250mA
14. Voltage regulation rate: ± 0.2.
15. Load regulation: ± 0.5.
16. Output ripple and noise (mVp-p): rated input voltage, full output, with 20MHZ bandwidth oscilloscope, the load side and 10uf and 0.1uf capacitance test
17. Switch overshoot amplitude: (rated input voltage, output plus 10%) ≤ 5% V0
18. Output over-current protection: output maximum load of 150 ~ 200%
19. Output short-circuit protection: Direct output when the normal short-circuit, short-circuit automatically removed to restore normal work (without damage to the whole machine)


Additional Information:

  • Minimum Order Quantity: 10 Number
  • Delivery Time: 2-4 days
Yes! I am Interested

HILINK PM01

REQUEST CALLBACK

HILINK PM01
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 280 / NumberGet Latest Price

Product features:

1. The ultra-thin, subminiature
2. The full voltage input (90 ~ 264 Vac)
3. Low ripple and low noise
4. Output overload short circuit protection function
5. High efficiency and power density
6. Product design to meet the EMC and safety testing requirements
7. Low power consumption, green environmental protection, no-load loss < 0.1 W
8.100% load test
9. Meet the requirements of UL, CE.

Environmental conditions:
 
Technical indicators:Single bit
Working temperature: - 20-60 +degree
Storage temperature: + 80-40 -degree
Relative humidity: 5-95%
The cooling way: Natural cooling
The atmospheric pressure: 80-106Kpa
The altitude :2000M or less
Vibration coefficient of 10 ~ 500 hz, 2 g10min. / 1 cycle, 60 min. Each along the X, Y, Z axes


Additional Information:

  • Minimum Order Quantity: 10 Number
  • Delivery Time: 2-4 days
Yes! I am Interested

HILINK 5M12

REQUEST CALLBACK

HILINK 5M12
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 320 / NumberGet Latest Price

Features:
1. Ultra-thin, ultra-small
2. Input voltage: 90 ~ 245V
3. Low power consumption, environmental protection, no-load loss <0.1W
4. Low ripple, low noise
5. Good output short-circuit and over-current protection and self-recovery
6. High efficiency, high power density
7. Input and output isolation voltage 3000V
8. 100% full load aging and testing
9. High reliability, long life design, continuous working time is more than 100,000 hours
10. Meet the UL / CE requirements: product design to meet EMC and safety test requirements
11. Moisture, vibration, water and dust to meet IP65 standards
Basic Parameters:
Operating temperature: -25 ~ 60 ℃
Storage temperature: -40 ~ 80 ℃
Relative humidity: 5 ~ 95%
Cooling method: natural cooling
Atmospheric pressure: 80 ~ 106 Kpa
Altitude: ≤ 2000m
Vibration coefficient: 10 ~ 500Hz, 2G10min / 1cycle 60min.each along X.Y, Z axes

Electrical Characteristics:

Rated input voltage: 90 ~ 245Vac
Input voltage range: 110-240V AC
The maximum input current: ≤ 0.2A
Input surge current: ≤10A
The maximum input voltage: ≤ 270V
Input low voltage efficiency: Vin = 110Vac, output full load ≥69%
Input high voltage efficiency: Vin = 2200Vac, output full load ≥70%
Long-term reliability: MTBF ≥ 100,000HExternal fuse Recommended: 1A / 250VacNo-load rated output voltage: 12.0 ± 0.1Vdc
Full load rated output voltage: 12.0 ± 0.2Vdc
Short time maximum output current: ≥540mALong time maximum output current: ≥ 450mA
Voltage regulation rate: ± 0.2%
Load regulation: ± 0.5%Output ripple and noise (mVp-p): rated input voltage, full output, with 20MHZ bandwidth oscilloscope, the load side and 10uf and 0.1uf capacitance test Switch overshoot amplitude: (rated input voltage, output plus 10%) ≤ 5% V0Output over-current protection: output maximum load of 110 ~ 150%
Output short-circuit protection: Direct output when the normal short-circuit, short-circuit automatically removed to restore normal work (without damage to the whole machine)


Additional Information:

  • Minimum Order Quantity: 10 Number
  • Delivery Time: 2-4 days
Yes! I am Interested

HILINK 5M05

REQUEST CALLBACK

HILINK 5M05
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 320 / NumberGet Latest Price

Features:
1. Meet UL, CE requirements,
2. Ultra-thin, ultra-small
3. All voltage input (AC: 90 ~ 240V)
4. Low ripple and low noise
5. Output overload and short circuit protection
6. High efficiency, high power density
7. The product is designed to meet the requirements of EMC and Safety Test
8. Low power consumption, environmental protection, no-load loss <0.1W
9.100% load aging and testing Environment Condition:

Item Name

Technical Criteria

Unit

Operation Temperature

-20—+60

Centigrade

Store Temperature

-40—+80

Centigrade

Relative humidity

5—95

%

Cooling way

Cooling by radiation

 

Atmospheric pressure

80—106

Kpa

Sea level elevation

≤2000

m

Vibration

Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes

 




Additional Information:

  • Minimum Order Quantity: 10 Number
  • Delivery Time: 2-4 days
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Micron
Heena Jain (Marketing Executive)
Shop No. 29/30, 2nd Floor, Yamuna Building Tara Temple Lane, Lamington Road, Girgaon,
Mumbai - 400007, Maharashtra, India
Call Us: 
Call Response Rate: 78%
Share Us :
F G T L



Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

© Micron. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Micron